Error Messages

Confirming error messages of the monitor

Message

Cause

Remedy

Output/

Indicator

Sensor system error happens.

Turn on sensor.

If not turned on, contact local

service center.

A system error occurred

in the sensor.

y

It is conceivable that a

fault occurred inside the

sensor.

y

Turn on the power of the sensor

again.

y

If the same error occurs, contact

your nearest KEYENCE office.

*1

Sensor internal memory reading

has failed.

Turn on or initialize sensor.

After this message is closed,

[Initialize] button will be displayed.

A memory read error

occurred when the

sensor started.

y

A data trouble occurred.

y

It is conceivable that

the power was switched

OFF during writing, or

noise was picked up.

y

Initialize the settings following

the instructions on the screen.

y

Turn on the power of the sensor

again.

y

Do not turn OFF the power

while saving the settings.

y

If the same error occurs, contact

your nearest KEYENCE office.

*1

Sensor program xx is damaged.

Initialization is necessary.

After this message is closed,

[Initialize] button will be displayed.

A memory read error

occurred when the

sensor started.

y

A data trouble occurred

during the execution of

program number xx.

y

It is conceivable that

the power was switched

OFF during writing, or

noise was picked up.

y

Initialize the settings following

the instructions on the screen.

y

Turn on the power of the sensor

again.

y

Do not turn OFF the power

while saving the settings.

y

If the same error occurs,

contact your nearest KEYENCE

office.

*1

Trigger error

A trigger error occurred.

Judgment processing has

not been executed.

y

If a target is to be

imaged using an

external trigger, the

external trigger will be

input during a BUSY

status.

y

If a target is to be

imaged using an

internal trigger, the

trigger interval will

become shorter than

the processing time.

y

An trigger error can be fixed

using one of the following

procedure.

y

Next normal trigger input

y

Clearing the Error input

y

Switching the program

number

y

Proceeding to the settings

screen of the sensor

y

Do not input the external trigger

during a BUSY status.

y

Set the trigger interval of the

internal trigger to a value that

is longer than the processing

time.

y

An error will not occur if the

trigger is set to [OFF] described

in output assignment for the

Settings Navigator (Page

4-60).

*2