Operation flow for the tool auto tuning, Starting and finishing the tool auto tuning, Operation flow for the tool auto tuning -16 – KEYENCE IV Series User Manual

Page 150: Starting and finishing the tool auto tuning -16

Advertising
background image

5-16

- IV Series User's Manual (Monitor) -

Tool Auto Tuning (Automatically Adjusting the Judgment Condition)

Operation flow for the Tool Auto

Tuning

High-quality

No

Yes

Low-quality

AutoTune as

OK

Automatically adjust the judgment

condition and threshold

Image a target

Select a starting

method

Select

the tool

Start

Finish

Judgment of an

image?

AutoTune as

NG

Add image?*

* There are three methods to prepare images.
* Up to 24 images can be used for tuning.

Starting and finishing the Tool Auto

Tuning

Displays the main screen for Tool Auto Tuning from
the Sensor Setup Menu screen.

y

The position adjustment tool is not a target for

Tool Auto Tuning.

y

The Color Area/Area tools with the [Fixed

Reference Area] set as [Enable] are excluded

from a Tool Auto Tuning target.

1

Display the Sensor Setup Menu screen.

“Displaying the Sensor Setup Menu Screen”

(Page 6-7)

2

Tap the [Tool Auto Tuning] button.

When the Tool Auto Tuning Guide screen
opens, tap the [Start] button.

3

If multiple tools are set in the program,

select the target tool for Tool Auto Tuning

from the pull-down menu, and tap the [OK]

button.

Select the tool

The Start Up Menu screen for Tool Auto Tuning
opens.

5

Operating/Adjusting