Achieving adequate image brightness, Correcting the distorted images due to, The installation -33 – KEYENCE IV Series User Manual

Page 167: Achieving adequate image brightness -33, If the brightness cannot be adjusted, In the auto brightness adjustment -33, Due to uneven brightness -33

Advertising
background image

5-33

- IV Series User's Manual (Monitor) -

Stabilizing the Judgment Process

Correcting the distorted images due to

the installation

If the sensor is not installed just in front of the target
due to the sensor installation restrictions and/or to
prevent a shine on the target’s surface, the target
image may become trapezoidally distorted.
The tilt correction corrects these images and
displays them without distortion.

“Tilt Correction” (Page 6-38)

Top view

Lateral view

Before tilt

correction

After tilt correction

(vertical)

Indicator light

Target

Target

Achieving adequate image brightness

If the image is too dark, the judgment process for
high and low-quality-targets becomes unstable due
to poor contrast. Also, if the image is too bright,
the judgment process may become unstable.
Brightness can be adjusted in Auto Brightness
Adjustment.

“Auto Brightness Adjustment” (Page 4-11)

z

„

If the brightness cannot be adjusted

in the Auto Brightness Adjustment

Finer brightness adjustments can be made in
Advanced Brightness Adjustment.

“Advanced Brightness Adjustment”

(Page 4-18)

z

z

Bright

Setting a higher brightness value gives a longer
exposure time, resulting in a brighter screen.

z

z

Imaging Mode

When "HighGain" is selected in the imaging
mode, the brightness amplification factor
increases and the screen becomes brighter.

z

„

If the brightness cannot be adjusted

due to uneven brightness

Refer to “Reducing the shininess of the
glossy or metal surface” (Page 5-35).