Setting the Trigger Options

A trigger in this manual indicates the timing to start imaging with the built-in camera of the sensor. In the
Trigger Options, set the timing to image a target within the field of view of this device. This device can
image a target at any timing, and can image continuously.

Settings for the Trigger Options

Items

Description

Setting range

Default

value

Trigger

(Trigger type)

Select the type of the timing to

start imaging.

y

Internal

Starts imaging continuously within

the time interval specified in the

trigger interval setting.

y

External

Starts imaging with the external

trigger synchronized with the

target's motion from a photoelectric

sensor or PLC installed outside.

The time (trigger delay) between

inputting the trigger until imaging

starts can be set.

Internal

Trigger interval

Set when the [Internal] is

selected in the trigger type

setting.
Set an interval (cycle) to

automatically start imaging.

1 to 10000 ms

50 ms

Trigger Delay

Set when the [External] is

selected in the trigger type

setting.
Used when the output timing

of the sensor for the trigger

occurrence and the imaging

timing of this device cannot be

synchronized.

This device starts imaging after

the time set in the trigger delay

of the trigger input passes.

0 to 1000 ms

0 ms

Trigger Options

Auto Brightness Adjustment Focus Adjustment Extended functions

1. Image Optimization

2. Master Registration

3. Tool Settings

4. Output Assignment

4

Settings Navigator (Setting the Judgment Condition)