Total status conditions, Total status conditions -65 – KEYENCE IV Series User Manual

Page 133

Advertising
background image

4-65

- IV Series User's Manual (Monitor) -

z

„

Total Status Conditions

1

Display the extended functions menu for

the Output Assignment.

“Display Method of Extended Functions

Menus” (Page 4-66)

2

Tap the [Total Status Conditions] button.

3

Select a total status condition.

The total status result is displayed in
accordance with the selected condition.

z

z

All Tools OK

When all of the detection tools were OK, the
total status output function turns ON.

Image of total status output when the total

status condition is [All Tools OK]

OK

Tool A

Tool B

Total

Status

OK

OK

NG

NG

NG

z

z

Any Tools OK

When any of the detection tools was OK, the
total status output function turns ON.

Image of total status output when the total

status condition is [Any Tools OK]

OK

Tool A

Tool B

Total

Status

OK

OK

NG

NG

NG

For [Any Tools OK], the status result of the

position adjustment is not included in the total

status conditions.

z

z

Logic 1 to 4

When the status result of the defined logic was
OK, the total status output function turns ON.

Image of total status output when the total

status condition is [Logic 1 to 4]

Logic

1 to 4

Total

Status

OK

OK

NG

NG

y

When the position adjustment failed, the

status result of each tool is NG.

y

If the Area tool window is protruded from

the imaging area when position adjustment

succeeded, the tool cannot be judged and

the status result is NG.

4

When the setting is completed, tap the

[OK] button.

The system returns to the main screen for the
Outline tool settings.

1. Image Optimization

2. Master Registration

3. Tool Settings

4. Output Assignment

Output Assignment

Extended functions

4

Settings Navigator (Setting the Judgment Condition)