Registering the images taken in the test mode, Registering the ok/ng images to be used, For the tool auto tuning -18 – KEYENCE IV Series User Manual

Page 152: Registering the images taken in, The test mode -18, Registering the images taken in the test

Advertising
background image

5-18

- IV Series User's Manual (Monitor) -

Tool Auto Tuning (Automatically Adjusting the Judgment Condition)

6

After the registration is completed, tap the

[Save] button.

The confirmation dialog appears.

7

Tap the [OK] button.

Adjusted results will be reflected and the
information dialog appears.

8

Tap the [OK] button.

By tapping the [Saving to the USB memory]

button, the result of Tool Auto Tuning can be

saved in the USB memory as a registration

information file and can be reused.

The system returns to the Sensor setup menu
screen.

Registering the OK/NG images to

be used for the Tool Auto Tuning

Registering the images taken in the

Test mode

Registers the image as an OK or an NG image to
perform tuning while preparing the multiple high and
low-quality-target and checking the images imaged.

1

Display the main screen for Tool Auto Tuning.

“Starting and finishing the Tool Auto Tuning”

(Page 5-16)

2

Tap the [Take a picture] button.

3

Image a high-quality-target to be the

criteria for the OK status or a low-quality-

target to be the criteria for NG status.

If the target is to be imaged using an external

trigger, input the external trigger.

If an external trigger cannot be input, tap the

button (Page 4-7) to image the target by

inputting an internal trigger temporarily. Imaging

by inputting an internal trigger finishes by the

button.

4

Check the displayed image and tap the

[AutoTune as OK] or [AutoTune as NG] button.

z

z

For Outline tool

The auto tuning will be performed and the OK
or NG image will be displayed.

5

Operating/Adjusting

Advertising