Mounting the attachment, Using the dome attachment, Mounting the dome attachment – KEYENCE IV Series User Manual

Page 38: Installed distance of the dome attachment, Mounting the attachment -6, Using the dome attachment -6, Mounting the dome attachment -6, Installed distance of the dome, Attachment -6

Advertising
background image

2-6

- IV Series User's Manual (Monitor) -

Mounting the Sensor

Mounting the attachment

Using the dome attachment

Dome attachment can be used for the standard
range type and short range type sensor.

y

Do not remove the front cover of the sensor.

y

Use the dome attachment at a correct

installation distance. Failure to do so may lose

the effect of the dome attachment.

y

Adjust the brightness with the dome attachment

mounted.

“Auto Brightness Adjustment” (Page 4-11)

y

For the color type, adjust the white balance with

the dome attachment mounted.

“White Balance (for color type only)” (Page 6-41)

z

„

Mounting the dome attachment

1

Mount the attachment by aligning the

concave part of the dome attachment with

the mounting screw of the front cover of

the sensor.

Concave part

Front cover

mounting screw

Concave part

Screw hole for

mounting the

attachment

2

Fix the dome attachment with attached

dedicated screws.

y

Screw : Dedicated screw x 2

Use the attached dedicated screws.

y

Tightening torque : 0.25 to 0.35 N·m

z

„

Installed distance of the dome

attachment

62 to 112 mm from the front face of the sensor
(0 to 50 mm from the front face of the dome attachment)

Target

Installed distance

from the front face

of the sensor

(0 to 50 mm)

62 to 1

12 mm

Sensor type

y

Standard range type

y

Short range type

2

Installation and Connection