6-34

- IV Series User's Manual (Monitor) -

Setting the Extended Functions of the Sensor

3

Tap the [Connection Test] button to

test the connection with the connection

destination.

The connection test is performed and the result
window opens.

If [Successfully connected.] is displayed, the
setting is completed.

When the test is executed, the connection with

the FTP server, folder creating at the transfer

destination, and data file creating are tested.

When the connection cannot be done properly,

deal with the problem in accordance with the

cause of connect failure displayed on the

result window.

“Remedy when data transfer via FTP is

unavailable” (Page A-38)

4

Tap the [OK] button.

The system returns to the FTP Destination
screen.

5

After the setting is completed, tap the [OK]

button.

The system returns to the main screen of the
FTP Settings.

z

„

Transfer Condition Settings

1

Tap the [Settings] button in the “Transfer

Condition”.

The Transfer Condition screen opens.

2

Set the file transfer conditions.

z

z

Transfer Condition

Selects the transfer condition of image data.

y

All ..................... Transfers all the images that

are judged.

y

NG Only ........... Transfers all the images whose

total status results are NG.

y

When the transfer condition is set to [All],

adjust the processing time so that all the

images can be transferred.

y

When the transfer could not be done on

time, the data are saved in the internal

buffer. The internal buffer can save images

up to 30 images.

y

Image data are transferred in the sequence that

they have been saved to the internal buffer.

y

When the remaining capacity of the internal

buffer is insufficient, an FTP error occurs and

the image data transfer fails.

y

When the transfer condition is set to [All],

confirm that there is sufficient storage area

on the FTP server.