Controlling timing of judgment with triggers, External trigger, Controlling timing of judgment with triggers -2 – KEYENCE IV Series User Manual

Page 232: External trigger -2, Controlling timing of judgment with triggers 7

Advertising
background image

7-2

- IV Series User's Manual (Monitor) -

Controlling Timing of Judgment with Triggers

For details of the trigger, refer to “Setting the Trigger Options” (Page 4-8).

External trigger

When the [Trigger Options] is set to [External], imaging and judgment are performed at the timing of
inputting the external trigger input.

(1)

(2)

(3)

Min 1.2 ms

Min

100 μs

Processing time

Trigger delay

Min 0.2 ms

External trigger input

BUSY output

Judgment process

(internal)

Trigger error output

Total status output

Status output of each tool

Position adjustment output

Output of each logic

Trigger 1

Max 2 ms

Previous result

Result from Trigger 1

Result from Trigger 2

Result from Trigger 4

Max 2 ms

ON

OFF

ON

OFF

ON

OFF

ON

OFF

(4)

(5)

Trigger 2

Trigger 3

Trigger 4

(1) Positions the target and inputs external trigger. The shortest input time is 100 μs for ON, and 1.2 ms for

OFF.

(2) BUSY output function turns ON. Processing time differs depending on the settings.
(3) After the trigger delay time (Page 4-8) elapses, the target is imaged and the judgment process is

performed.

(4) After the judgment process is completed, it updates status output and the BUSY output function is

turned OFF. Confirms that the BUSY output is turned OFF, then imports the status output.

(5) If the external trigger is input while the BUSY is being output, the input is ignored and a trigger error

occurs. Trigger 3 is not judged. To output the trigger error, set the trigger error within the Output
Assignment (Page 4-60) under Settings Navigator to [ON].

y

The ON status of each output is as follows.
When Output Settings (Page 6-27) are [N.O.]

: Status with NPN or PNP open collector ON.

When Output Settings (Page 6-27) are [N.C.]

: Status with NPN or PNP open collector OFF.

y

The ON status of each input indicates 0 V line is shorted when the Polarity (Page 6-28) is NPN, and
indicates that voltage is applied within the 0 V line when the Polarity is PNP.

y

The edge trigger for activating timing or in deactivating timing can be set for the external trigger input.

“Input Settings” (Page 6-26)

y

The trigger error output function turns OFF when the next trigger is activated, when the error is cleared,
when the program is switched, or when the system moves to the settings screen.

y

When the output mode (Page 6-27) of status output is set to [Latching]. When the output mode is set to
[One-Shot], refer to “Changing the timing of the status output” (Page 7-6).

Controlling Timing of Judgment with Triggers

7

Controlling with the Input/Output Line

Advertising