Mounting the sensor, Checking the view and installed distance, Mounting the sensor -2 – KEYENCE IV Series User Manual

Page 34: Checking the view and installed distance -2, Mounting the sensor 2

Advertising
background image

2-2

- IV Series User's Manual (Monitor) -

Mounting the Sensor

y

Ground (functional ground) the drain cable

(FG) of the power I/O cable.

y

Mount and insulate the sensor. Use the

attached mounting adapter to insulate.

Sensor case has been grounded. If the sensor

is not insulated, the electric potential and

noises may cause a damage or malfunction.

y

Do not place the sensor in the environment

that exceeds the limit of sensor's resistance

to the environment, or environment that

propagates the vibration directly to the

sensor. Those may cause a damage or

malfunction.

y

Manual focus type needs to adjust the focusing

position after installed. Reserve the enough

space to adjust and install it.

y

At the time of installation, it is better to enable

the position or direction adjustment of the

sensor by installing the adjustment system at

the sensor mounting area.

y

View and optical axis have individual differences.

Adjust the position by checking the actual image

at the time of installation.

y

Place the sensor where no ambient light has

effect. Ambient light includes solar light, lights of

other devices, and photoelectric sensors. Also,

be careful when the light intensity of the ambient

light changes. Use the shield to protect when the

location cannot be changed.

y

Place the sensor where no object can block out

the internal light or the view of the sensor.

y

Detection may become unstable due to the

lights if multiple sensors are placed nearby each

other. Delay the timing of external trigger or use

the shield to avoid interference.

Checking the view and installed

distance

For IV Series, installed distance between the view
and object is different depending on the type of the
sensor. Check the type of the sensor to be used
and its view, and place it in the proper distance.

View H

View V

Installed distance

WD

Indicator light

View V = View H x 0.75

(H : V = 4 : 3)

The indicator light of

the sensor side is the

front surface of an

image.

Mounting the Sensor

2

Installation and Connection

Advertising