Device security setup, Device security setup -17 – Basler Electric DGC-2020 User Manual

Page 127

Advertising
background image

L

Application Version: Read-only value obtained when BESTCOMSPlus is communicating with an

optional LSM-2020.

M

Boot Code Version: Read-only value obtained when BESTCOMSPlus is communicating with an

optional LSM-2020.

N

Application Build Date: Read-only value obtained when BESTCOMSPlus is communicating with an

optional LSM-2020.

O

Serial Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional

LSM-2020.

P

Application Part Number: Read-only value obtained when BESTCOMSPlus is communicating with an

optional LSM-2020.

Q

Model Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional

LSM-2020.

R

Application Version: Read-only value obtained when BESTCOMSPlus is communicating with an

optional CEM-2020.

S

Boot Code Version: Read-only value obtained when BESTCOMSPlus is communicating with an

optional CEM-2020.

T

Application Build Date: Read-only value obtained when BESTCOMSPlus is communicating with an

optional CEM-2020.

U

Serial Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional

CEM-2020.

V

Application Part Number: Read-only value obtained when BESTCOMSPlus is communicating with an

optional CEM-2020.

W

Model Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional

CEM-2020.

X

Application Version: Read-only value obtained when BESTCOMSPlus is communicating with an

optional AEM-2020.

Y

Boot Code Version: Read-only value obtained when BESTCOMSPlus is communicating with an

optional AEM-2020.

Z

Application Build Date: Read-only value obtained when BESTCOMSPlus is communicating with an

optional AEM-2020.

AA

Serial Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional

AEM-2020.

BB

Application Part Number: Read-only value obtained when BESTCOMSPlus is communicating with an

optional AEM-2020.

CC

Model Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional

AEM-2020.

Device Security Setup

Password protection guards against unauthorized changing of DGC-2020 settings. DGC-2020 passwords
are case sensitive. Three levels of password protection are available. Each level is described in the
following paragraphs.

•

OEM Access. This password level allows access to all settings. The default, OEM-access password
is OEM.

•

Settings Access. This password level allows all except uploading of firmware and clearing of device
event log. The default, settings-access password is SET.

•

Operator Access. The default, operator-access password is OP. This password level allows all
settings to be read and allows changes to be made to the following:

o

LCD Contrast

o

Sleep Mode

o

Date/Time

o

All Sender Fail Time Delays

o

Metric Conversion

o

Low Fuel Pre-Alarm Level

o

Low Fuel Alarm Level

o

Pre-Start Contact after Cranking

o

Cooldown Time

o

Pre-Crank Time Delay

9400200990 Rev X

DGC-2020 BESTCOMSPlus

® Software

4-17

Advertising
This manual is related to the following products: