Basler Electric DGC-2020 User Manual

Page 53

Advertising
background image

■

MODULE TYPE (Visible when ECU is configured for MTU MDEC or MTU ECU7/ECU8.)

■

ALIVE MSG (Visible when ECU is configured for MTU MDEC or MTU ECU7/ECU8.)

■

SPEED SETUP (Visible when ECU is configured for (MTU ADEC, MTU MDEC 304, MTU
ECU7/ECU8, or MTU Smart Connect.)

□

J1939 RPM ENABLE (Visible when ECU is configured for Standard, Volvo Penta,
MTU ADEC, GM/Doosan, Cummins, or MTU Smart Connect.)

□

ENGINE RPM

□

RPM BAND WIDTH

□

IDLE RPM

□

SPEED UP (Visible when ECU is configured for MTU ADEC, MTU MDEC 304, MTU
ECU7/ECU8, or MTU Smart Connect.)

□

SPEED DN (Visible when ECU is configured for MTU ADEC, MTU MDEC 304, MTU
ECU7/ECU8, or MTU Smart Connect.)

□

TEST OVRSPEED (Visible when ECU is configured for MTU ADEC, MTU MDEC
304, MTU ECU7/ECU8, or MTU Smart Connect.)

□

SPD DMAND SRC (Visible when ECU is configured for MTU MDEC 304, MTU
ECU7/ECU8, or MTU Smart Connect.)

□

IDLE REQUEST (Visible when ECU is configured for MTU MDEC 304, MTU
ECU7/ECU8, or MTU Smart Connect.)

□

INCREASE IDLE (Visible when ECU is configured for MTU MDEC 304, or MTU
ECU7/ECU8.)

■

ECU SETUP (Visible when ECU is configured for MTU ADEC, MTU ECU7/ECU8, or MTU
Smart Connect.)

□

TRIP RESET (Visible when ECU is configured for MTU ECU7/ECU8.)

□

INT OIL PRIME

□

GOV PRM SW (Visible when ECU is configured for MTU ADEC or MTU Smart
Connect.)

□

ENG STRT PRIME (Visible when ECU is configured for MTU ECU7/ECU8.)

□

FAN OVERRIDE (Visible when ECU is configured for MTU ECU7/ECU8.)

□

MODE SWITCH (Visible when ECU is configured for MTU ECU7/ECU8.)

□

GOV PARAM SET (Visible when ECU is configured for MTU ECU7/ECU8.)

□

CAN RATING SW 1 (Visible when ECU is configured for MTU ECU7/ECU8.)

□

CAN RATING SW 2 (Visible when ECU is configured for MTU ECU7/ECU8.)

□

DIS CYL CUT 1 (Visible when ECU is configured for MTU ECU7/ECU8.)

□

DIS CYL CUT 2 (Visible when ECU is configured for MTU ECU7/ECU8 or MTU Smart
Connect.)

□

OPERATING MODE (Visible when ECU is configured for MTU Smart Connect.)

●

MODEM SETUP

○

DIALOUT X (X = 1 TO 4)

○

PAGER ID X (X = 1 TO 4)

○

RINGS FOR ANSWER

○

OFFLN DELAY

○

DIALOUT DLY

○

PGR BUFF LMT

○

PGR COM

●

RS485 SETUP

○

COMM BAUD

○

COMM PARITY

○

MODBUS ADDR

○

LEGACY MODBUS

SYSTEM PARAMS

●

SYSTEM SETTINGS

○

GEN CONNECT

○

BUS CONNECT

○

RATED kW

○

RATED VOLTS

○

RATED FREQ

○

ALTRNATE FRQ

○

RATED RPM

○

RATED PF

○

ROTATION

○

SYSTEM TYPE

9400200990 Rev X

DGC-2020 Human-Machine Interface

2-13

Advertising