DCM1 & DCM1e Installation and User Guide V1.0

64

connectors

of the two DCM1s. The paging commands for

Zones 1 to 8 should be wired to the

PAGING ACCESS

connector of DCM1 #1, and those for Zones 9 to 16 to that
of DCM1 #2. The general wiring procedures described at
page 26 should be followed.

Music Mute Input

The

MUSIC MUTE inputs on the two DCM1s can be

paralleled together, though this is not ideal. A preferred
solution, if available, is to use a separate set of emergency
system contacts for each DCM1 making up the system.

RS-232 Control

If the DCM1s are to be controlled via RS-232 by an
external control system, the two DCM1s should be treated
independently. Connect each DCM1’s

RS232 INTERFACE

to a separate RS2-32 port on the system controller. The
controller should be programmed to address each unit

independently.

Ethernet interface

Two DCM1e’s should each have their ETHERNET
INTERFACE

port connected to two separate ports on

the network switch. Ensure that the units have different IP

addresses. Each unit can then be controlled via the browser
interface independently.