Torch mounting and alignment -19, Power supply to cnc interface cable -34, Power supply to cnc interface cable – Hypertherm HSD130 HySpeed Plasma User Manual

Page 102

Advertising
background image

INSTALLATION

3-34

HySpeed HSD130 RHF

Instruction Manual

Wire

Input/

Input/

color

Pin no.

Output

Signal name

Function

Output

Notes

Black

1

Input

None

Not used

Output

Red

20

Input

None

Not used

Output

Black

2

Output

None

Not used

Input

Green

21

Output

None

Not used

Input

Black

3

None

Not used

Blue

22

None

Not used

Black

4

Output

Motion E (-)

Notifies the CNC that an arc transfer has occurred and to begin

Input

2

Yellow

23

Output

Motion C (+)

machine motion once the CNC’s pierce delay has timed out.

Input

Black

5

Output

None

Not used

Input

2

Brown

24

Output

None

Not used

Input

Black

6

Output

Rampdown error E (-)

Notifies the CNC that a rampdown error has occurred

Input

2

Orange

25

Output

Rampdown error C (+)

Red

7

Output

None

Not used

Input

2

White

26

Output

None

Not used

Red

8

Output

None

Not used

Input

2

Green

27

Output

None

Not used

Input

Red

9

Output

None

Not used

Input

2

Blue

28

Output

None

Not used

Input

Red

10

Output

None

Not used

Input

2

Yellow

29

Output

None

Not used

Input

Red

11

None

Not used

Brown

30

None

Not used

Red

12

Input

Corner -

CNC Notifies the plasma system that a corner is approaching and to

Output

1

Orange

31

Input

Corner +

reduce cut current (Cut current is CNC selectable or defaults to 75%.

Output

of cut current)

Green

13

Input

Pierce -

CNC Notifies the plasma system to maintain the shield preflow until

Output

1

White

32

Input

Pierce +

the CNC releases the signal.

Green

14

Input

Hold -

Not required without Command THC. Command THC requires signal

Output

1

Blue

33

Input

Hold +

to preflow gases during IHS.

Green

15

Input

Start -

CNC initiates the plasma arc.

Output

1

Yellow

34

Input

Start +

Output

Green

16

None

Not used

Brown

35

None

Not used

Green

17

None

Not used

Orange

36

Power ground

Ground

White

18

Power ground

Ground

Black

37

CNC +24 VDC

Available 24 VDC (200 milliamps maximum) See notes

3

19

CNC + 24 VDC

Not connected

Power supply to CNC interface cable

8

Power supply

CNC

Part no.

Length

123022

7.5 m (25 ft)

123023

15 m (50 ft)

Advertising