System components -5, Placement of the power supply -13, Placement of the power supply a – Hypertherm HSD130 HySpeed Plasma User Manual

Page 81

Advertising
background image

INSTALLATION

HySpeed HSD130 RHF

Instruction Manual

3-13

Placement of the power supply

A

The power supply can be moved by forklift but the forks must be long enough to extend the entire length of the base.
Take care when lifting so that the underside of the power supply is not damaged.

Place the power supply in an area that is free of excessive moisture, has proper ventilation, and is relatively
clean. Allow 1 m (3 ft) on all sides of the power supply for ventilation and servicing.

• Cooling air is drawn in through the front panel and is exhausted through the rear of the unit by a cooling fan.

Do not place any filter device over the air intake locations, which reduces cooling efficiency and VOIDS
THE WARRANTY.

• Do not place the power supply on an incline greater than 10° to prevent it from toppling.

DANGER

E

LECTRICAL SHOCK CAN KILL

R

emove all electrical connections to power supply before moving or positioning.

Transporting the unit can cause personal injury and equipment damage.

Advertising