Mild steel, Plasma / air shield 50 a cutting, Metric – Hypertherm HSD130 HySpeed Plasma User Manual

Page 125: English

Advertising
background image

OPERATION

HySpeed HSD130 RHF

Instruction Manual

4-11

Mild steel

O

2

Plasma / Air Shield

50 A Cutting

Flow Rates – lpm/scfh

O

2

Air

Preflow

0 / 0

69 / 146

Cutflow

29 / 62

73 / 155

220532

220530

220529

220528

Metric

Plasma

Shield

Plasma

Shield

mm

Volts

mm

factor %

seconds

0.5

98

3.0

200

0.0

0.8

98

3.0

200

0.0

1.0

98

3.0

200

0.1

1.2

98

3.0

200

0.1

1.5

98

3.0

200

0.1

2.0

98

3.0

200

0.1

2.5

100

3.6

200

0.2

3.0

102

3.6

200

0.3

4.0

104

4.0

200

0.4

6.0

108

5.0

200

0.5

English

Plasma

Shield

Plasma

Shield

in

Volts

in

factor %

seconds

.018

98

0.120

200

0.0

.024

98

0.120

200

0.0

.030

98

0.120

200

0.0

.036

98

0.120

200

0.1

.048

98

0.120

200

0.1

.060

98

0.120

200

0.1

.075

98

0.120

200

0.1

.105

100

0.140

200

0.2

.135

103

0.140

200

0.3

3/16

106

0.180

200

0.4

1/4

108

0.200

200

0.5

72

36

85

65

240

220

160

130

290

280

270

260

3650

2800

1750

300

6600

6150

5400

4300

.090

.100

1.5

1.5

1.5

1.5

1.5

1.5

1.8

1.8

.060

.060

.070

.070

O

2

Air

.060

.060

.060

.060

.060

Material

Thickness

Pierce Delay

Time

in

ipm

Arc

Voltage

Torch-to-Work

Distance

Initial Pierce Height

O

2

Air

Select
Gases

Set

Cutflow

72

36

Initial Pierce Height

Pierce Delay

Time

Select
Gases

Set

Cutflow

Material

Thickness

Arc

Voltage

mm

mm/m

Cutting Speed

Torch-to-Work

Distance

Cutting Speed

2.0

2.5

7550

7050

6775

220578

220490 (no IHS tab)