INSTALLATION

3-22

HySpeed HSD130 RHF

Instruction Manual

Fuel gas console to power supply connections

Before connections from the power supply to the fuel-gas console are made, the standard air hose must be removed
from the power supply.

1. Remove and discard the standard air hose.

2. The air hose for the power supply to the fuel-gas console connection is supplied with the fuel-gas console. Connect

the hose (024819) from the air filter on the power supply to the air inlet on the fuel-gas console.

1f

1b

Remove the

standard

air hose

Install the

fuel-gas
air hose

The air supply
line must be
connected
here