Aluminum, Air plasma / air shield 45 a cutting, Metric – Hypertherm HSD130 HySpeed Plasma User Manual

Page 134: English

Advertising
background image

OPERATION

4-20

HySpeed HSD130 RHF

Instruction Manual

Aluminum

Air Plasma / Air Shield

45 A Cutting

220532

220525

220529

220528

Metric

Plasma

Shield

Plasma

Shield

mm

Volts

mm

factor %

seconds

0.5

113

3.0

200

0.0

0.8

116

3.0

200

0.1

1.0

117

3.6

200

0.1

1.2

118

3.6

200

0.2

1.5

119

3.6

200

0.2

2.0

120

4.0

200

0.2

2.5

120

4.0

200

0.3

3.0

121

4.0

200

0.3

4.0

122

4.6

200

0.4

6.0

130

5.0

200

0.5

English

Plasma

Shield

Plasma

Shield

in

Volts

in

factor %

seconds

0.016

113

0.120

200

0.0

0.020

114

0.120

200

0.0

0.025

115

0.120

200

0.0

0.032

116

0.120

200

0.1

0.040

117

0.140

200

0.1

0.051

118

0.140

200

0.2

0.064

119

0.140

200

0.2

0.081

120

0.160

200

0.2

0.102

120

0.160

200

0.3

1/8

121

0.160

200

0.3

3/16

122

0.180

200

0.4

1/4

130

0.200

200

0.5

62

73

62

73

.090

.100

40

65

.060

.060

.060

.060

.070

.070

.070

.080

.080

150

110

90

.080

270

250

220

185

1950

1150

310

300

5000

3950

2950

2400

7600

6900

6350

5800

2.0

2.0

2.3

2.5

Set

Cutflow

Select
Gases

Torch-to-Work

Distance

Cutting Speed

1.5

1.5

1.8

1.8

1.8

2.0

Pierce Delay

Time

mm

mm/m

Air

Air

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting Speed

Initial Pierce Height

Pierce Delay

Time

in

ipm

Select
Gases

Set

Cutflow

Material

Thickness

Arc

Voltage

Initial Pierce Height

Air

Air

290

Flow Rates – lpm/scfh

Air

Preflow

149 / 315

Cutflow

161 / 342

220578

220490 (no IHS tab)