INSTALLATION

HySpeed HSD130 RHF

Instruction Manual

3-39

Connect the power

1. Insert the power cable through the strain relief at the rear of the power supply.

2. Connect the ground lead (PE) to the ground terminal as shown below.

3. Connect the power leads to the terminals as shown below.

4. Check that the line disconnect switch is in the OFF position and remains in the OFF position for the

remainder of the installation of the system.

5. Connect the power cord leads to the line disconnect switch, following national and local electrical codes.

Line

disconnect

switch

Power

cable

L1

GND

North American wire colors

U = Black
V = White
W = Red
(PE) Earth ground = Green/Yellow

European wire colors
U = Black
V = Blue
W = Brown
(PE) Earth ground = Green/Yellow

L2

L3

L1

GND

L2

L3

Non-CE power supply

CE power supply

L1 = White

L2 = Red

L3 = Black

GND = Green

DANGER

E

LECTRICAL SHOCK CAN KILL

T

he line disconnect switch must be in the OFF position before making the power cable connections.

In the U.S., use a “lock-out/tag-out” procedure until installation is complete. In other countries,
follow appropriate national and local safety procedures.