Power supply -7 – Hypertherm HSD130 HySpeed Plasma User Manual

Page 63

Advertising
background image

SpecificationS

HySpeed HSD130 RHF

Instruction Manual

2-7

power supply

286.3 kg

631 lb

1073.2 mm

42.25”

1117.6 mm

44.0”

571.5 mm

22.5”

General
Maximum OCV (U

0

)

311 VDC

Maximum output current (I

2

)

130 Amps

Output voltage (U

2

)

50 – 150 VDC

Duty cycle rating (X)

100% @ 19.5 kw, 40° C (104° F)

Ambient temperature/Duty cycle

Power supplies will operate between -10° C and +40° C (+14° and 104° F)

Power factor(cosϕ)

0.91 @ 130 ADC output

Cooling

Forced air (Class F)

Insulation

Class H

part

number

ac Voltage

(U

1

)

phase

frequency

(Hz)

amperage (i

1

)

Regulatory

approval

power kW

(+/- 10%)

(U

1

x i

1

x 1.73)

078515

200/208

3

50/60

62/60

CSA

21.5

078516

220

3

50/60

56

CSA

21.5

078517

240

3

60

52

CSA

21.5

078518

380

3

*50/60

33

CCC

21.5

078519

400

3

50/60

32

CE/GOST-R

21.5

078520

440

3

50/60

28

CSA

21.5

078521

480

3

60

26

CSA

21.5

078522

600

3

60

21

CSA

21.5

* 380 V CCC regulatory approval is for 50 Hz operation only.