Stainless steel, Air plasma / air shield 130 a cutting, Metric – Hypertherm HSD130 HySpeed Plasma User Manual

Page 131: English

Advertising
background image

OPERATION

HySpeed HSD130 RHF

Instruction Manual

4-17

Stainless steel

Air Plasma / Air Shield

130 A Cutting

220536

220492

220488

220487

Metric

Plasma

Shield

Plasma

Shield

mm

Volts

mm

factor %

seconds

6

143

7.2

200

0.3

10

148

8.2

200

0.5

12

148

8.2

200

0.8

15

158

20

160

English

Plasma

Shield

Plasma

Shield

in

Volts

in

factor %

seconds

1/4

143

.280

200

0.3

3/8

148

.320

200

0.5

1/2

148

.320

200

0.8

5/8

158

3/4

160

Edge Start

Edge Start

72

35

72

35

20

.140

.160

.160

.180

.180

100

70

50

30

1700

1380

900

430

Air

Air

Air

Air

3.6

4.1

4.1

4.6

Initial Pierce Height

Pierce Delay

Time

in

ipm

mm

mm/m

Select
Gases

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting Speed

4.6

2600

Torch-to-Work

Distance

Cutting Speed

Initial Pierce Height

Pierce Delay

Time

Select
Gases

Set

Cutflow

Material

Thickness

Arc

Voltage

Flow Rates – lpm/scfh

Air

Preflow

67 / 142

Cutflow

132 / 280

220578

220490 (no IHS tab)