Stainless steel, Air plasma / air shield 130 a cutting, Metric – Hypertherm HSD130 HySpeed Plasma User Manual
Page 131: English

OPERATION
HySpeed HSD130 RHF
Instruction Manual
4-17
Stainless steel
Air Plasma / Air Shield
130 A Cutting
220536
220492
220488
220487
Metric
Plasma
Shield
Plasma
Shield
mm
Volts
mm
factor %
seconds
6
143
7.2
200
0.3
10
148
8.2
200
0.5
12
148
8.2
200
0.8
15
158
20
160
English
Plasma
Shield
Plasma
Shield
in
Volts
in
factor %
seconds
1/4
143
.280
200
0.3
3/8
148
.320
200
0.5
1/2
148
.320
200
0.8
5/8
158
3/4
160
Edge Start
Edge Start
72
35
72
35
20
.140
.160
.160
.180
.180
100
70
50
30
1700
1380
900
430
Air
Air
Air
Air
3.6
4.1
4.1
4.6
Initial Pierce Height
Pierce Delay
Time
in
ipm
mm
mm/m
Select
Gases
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting Speed
4.6
2600
Torch-to-Work
Distance
Cutting Speed
Initial Pierce Height
Pierce Delay
Time
Select
Gases
Set
Cutflow
Material
Thickness
Arc
Voltage
Flow Rates – lpm/scfh
Air
Preflow
67 / 142
Cutflow
132 / 280
220578
220490 (no IHS tab)