INSTALLATION
HySpeed HSD130 RHF
Instruction Manual
3-37
Examples of input circuits
Output from
CNC/PLC
External relay
(AC or DC)
1. Relay interface
+24 VDC
HSD
Power
ground
2. Optocoupler interface
CNC/PLC
+24 VDC
HSD
Power
ground
Transistor-output
optocoupler
24VDC
CNC/PLC
+24 VDC
HSD
Power
ground
Power
ground
Active-high drive
3. Amplified-output interface
Note:
The external relay's life may be improved by adding a
metallized-polyester capacitor (0.022µF 100V or higher) in
parallel with the relay contacts.
°