MAINTENANCE

HySpeed HSD130 RHF

Instruction Manual

5-9

Error code troubleshooting (3 of 8)

Error code

number

Name

Description

Corrective action

043

High preflow

pressure

Gas pressure is above the
upper limit of 6.8 bar
(99 psi)

1. Verify gas supply pressure settings.
2. Verify gas regulator settings on gas console with cut chart.
3. See Setting the supply regulators (Installation section).
4. Solenoid at off-valve is not opening. Verify power to valves,

disconnect plasma and shield hoses exiting off-valve. If
pressures decrease, a valve is not functioning or no power
to the valve.

044

Low plasma

gas pressure

Gas pressure is below the
lower limit of 3.5 bar
(50 psi)

1. Inspect gas supply pressure and volume of gas remaining in

supply tanks.

2. Verify gas regulator settings on the front panel of the power

supply with cut chart.

3. See Setting the supply regulators (Installation section).
4. Fuel-gas only – Perform leak test procedure

(Maintenance section).

045

High plasma

gas pressure

Gas pressure above the
upper limit of 6.8 bar
(99 psi)

1. Verify gas supply pressure settings.
2. Verify plasma gas regulator settings on the front panel of the

power supply with cut chart.

3. See Setting the supply regulators (Installation section).
4. Solenoid at off-valve is not opening. Verify power to valves,

disconnect plasma and shield hoses exiting off-valve. If
pressures decrease, a valve is not functioning or no power
to the valve.

046

Low line

voltage

Line voltage is close to or
below the lower limit of
102 VAC (120 VAC
–15%). The normal lower
limit for operation is 108
VAC (120 VAC –10%).

1. Verify input-line voltage. Voltage needs to be within 10 % of

nominal (120 VAC).

2. Verify fuses on PCB3.
3. Verify 120 VAC voltage on plug J3.4, pins 3 and 4 on

PCB3.

4. If AC voltage on J3.4, pins 3 and 4, is greater than

108 VAC, replace PCB3.

047

High line

voltage

Line voltage is close to or
above the upper limit of
138 VAC (120 VAC
+15%). The normal upper
limit for operation is 132
VAC (120 VAC +10%).

1. Verify input-line voltage. Voltage needs to be within 10 % of

nominal (120 VAC).

2. Verify fuses on PCB3.
3. Verify 120 VAC voltage on plug J3.4, pins 3 and 4 on

PCB3.

4. If AC voltage on J3.4, pins 3 and 4, is less than

132 VAC, replace PCB3.