Maximize the life of consumable parts -13, Error code troubleshooting – 4 of 8 -10 – Hypertherm HSD130 HySpeed Plasma User Manual

Page 156

Advertising
background image

MAINTENANCE

5-10

HySpeed HSD130 RHF

Instruction Manual

Error code troubleshooting (4 of 8)

Error code

number

Name

Description

Corrective action

050

Start signal is

on at

power-up

Plasma start signal input is
active during power-up of
the power supply.

1. Stop or clear the cutting program. The plasma start signal

to the plasma was not dropped after the last cut.

2. Verify that the CNC interface cable is not damaged.
3. Remove CNC interface cable from PCB4 and look for an

open circuit between pins 15 and 34.

4. If the circuit is closed either the CNC is issuing a plasma

start or the CNC interface cable is damaged.

5. If circuit is open, and D44 is illuminated with the CNC

Interface cable removed from PCB4, replace PCB4.

053

Low shield

pressure

Shield pressure is below
lower limit of 0.14 bar
(2 psi).

1. Verify gas supply pressure and that a sufficient volume of

gas remains in your supply.

2. Verify gas regulator settings on the front panel with cut

chart.

3. See Setting the supply regulators (Installation section).
4. Fuel-gas only – Perform leak test procedure

(Maintenance section).

054

High shield

pressure

Shield gas pressure is
above upper limit of
6.8 bar (99 psi).

1. Verify gas supply regulator settings. See Setting the

supply regulators (Installation section).

2. Verify pressure settings on the front panel with cut chart.
3. Solenoid at off-valve is not opening. Verify power to valves,

disconnect plasma and shield hoses exiting off-valve. If
pressures decrease, a valve is not functioning or no power
to the valve.

061

No plasma

gas type

Plasma gas has not been
selected.

1. If you have a base system (no fuel-gas console), replace

the control board (PCB4)

2. If the system has a fuel gas console, replace the fuel-gas

console control board (PCB2)

062

No shield gas

type

Shield gas has not been
selected.

1. If you have a base system (no fuel-gas console), replace

the control board (PCB4)

2. If the system has a fuel gas console, replace the fuel-gas

console control board (PCB2)

063

Low preflow

inlet pressure

Inlet pressure is < 4.1 bar
(60 psi).

1. Verify Air or nitrogen gas supply pressure and that a

sufficient volume of gas remains in your supply.

2. Verify that the Burkart valve is functioning properly.
3. Put the selection switch in the SET position. The 3-digit

LED shows the supply pressure. The pressure reading
should be between 6.2 bar and 8.3 bar
(90 psi and 120 psi).

1

Advertising