6 basic drive setup adjustments, Table 4.21 high starting torque, settings 8 to b, Table 4.22 constant output, settings c to f – Yaskawa CIMR-PUxA User Manual

Page 105: Table 4.25 high starting torque, settings 8 to b

Advertising
background image

Table 4.21 High Starting Torque, Settings 8 to B

Setting = 8

50 Hz

Setting = 9

50 Hz

Setting = A

60 Hz

Setting = B

60 Hz

0

9

200

1.3 2.5

50

18

V

oltage (V)

Frequency (Hz)

V

oltage (V)

Frequency (Hz)

0

11

200

1.3 2.5

50

23

V

oltage (V)

Frequency (Hz)

0

9

200

1.5 3

60

18

0

13

200

1.5 3

60

23

V

oltage (V)

Frequency (Hz)

Table 4.22 Constant Output, Settings C to F

Setting = C

90 Hz

Setting = D

120 Hz

Setting = E

180 Hz

Setting = F

60 Hz

0

7

14

200

1.5 3

90

60

V

oltage (V)

Frequency (Hz)

0

7

14

200

1.5 3

120

60

V

oltage (V)

Frequency (Hz)

0

7

14

200

1.5 3

180

60

V

oltage (V)

Frequency (Hz)

V

oltage (V)

Frequency (Hz)

0

8.1

16.1

230

1.5 3

60

Predefined V/f Patterns for Models 2A0250 to 2A0415, 4A0139 to 4A1200, and 5A0099 to 5A0242

The values in the following graphs are specific to 200 V class drives. Double the values for 400 V class drives. Multiply the

values by 2.875 for 600 V class drives.

Table 4.23 Rated Torque Characteristics, Settings 0 to 3

Setting = 0

50 Hz

Setting = 1

60 Hz

Setting = 2

60 Hz

Setting = 3

72 Hz

0

6

200

1.3 2.5

50

12

V

oltage (V)

Frequency (Hz)

0

6

200

1.5 3

60

12

V

oltage (V)

Frequency (Hz)

0

6

12

200

1.5 3

60

50

V

oltage (V)

Frequency (Hz)

0

6

12

200

1.5 3

72

60

V

oltage (V)

Frequency (Hz)

Table 4.24 Derated Torque Characteristics, Settings 4 to 7

Setting = 4

50 Hz

Setting = 5

50 Hz

Setting = 6

60 Hz

Setting = 7

60 Hz

0

5

200

1.3

25

50

35

V

oltage (V)

Frequency (Hz)

0

6

200

1.3

25

50

50

V

oltage (V)

Frequency (Hz)

0

5

200

1.5

30

60

35

V

oltage (V)

Frequency (Hz)

0

6

200

1.5

30

60

50

V

oltage (V)

Frequency (Hz)

Table 4.25 High Starting Torque, Settings 8 to B

Setting = 8

50 Hz

Setting = 9

50 Hz

Setting = A

60 Hz

Setting = B

60 Hz

0

7

200

1.3 2.5

50

15

V

oltage (V)

Frequency (Hz)

0

9

200

1.3 2.5

50

20

V

oltage (V)

Frequency (Hz)

0

7

200

1.5 3

60

15

V

oltage (V)

Frequency (Hz)

0

11

200

1.5 3

60

20

V

oltage (V)

Frequency (Hz)

4.6 Basic Drive Setup Adjustments

YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide

105

4

Start-Up Programming & Operation