Drive fails to operate properly due to noise

interference

• Review the possible solutions provided for handling noise interference.
• Review the section on handling noise interference and check the control circuit lines, main circuit lines,

and ground wiring.

Overexcitation gain is set too high

• Check if the fault occurs simultaneously with overexcitation function operation.
• Consider motor flux saturation and reduce the value of n3-13 (Overexcitation Deceleration Gain).

Run command was applied while motor was

coasting

• Set b3-01 to 1 to enable Speed Search at Start.
• Program the Speed Search command input through one of the multi-function contact input terminals

(H1-oo = 61 or 62).

The rated output current of the drive is too

small

Use a larger drive.

Digital Operator Display

Fault Name

oFA00

Option Card Connection Error at Option Port CN5-A
Option compatibility error

oFA01

Option Card Fault at Option Port CN5-A
Option not properly connected

to

oFA03 to oFA06

Option Card Error Occurred at Option Port CN5-A

,

oFA10, oFA11

to

oFA12 to oFA17

Option Card Connection Error (CN5-A)

to

oFA30 to oFA43

Communication Option Card Connection Error (CN5-A)

oFb00

Option Card Fault at Option Port CN5-B
Option compatibility error

oFb01

Option Card Fault at Option Port CN5-B
Option not properly connected

oFb02

Option Card Fault at Option Port CN5-B
Same type of option card is currently connected

to

oFb03 to oFb11

Option card error occurred at Option Port CN5-B

to

oFb12 to oFb17

oFC00

Option Card Connection Error at Option Port CN5-C
Option compatibility error

oFC01

Option Card Fault at Option Port CN5-C
Option not properly connected

oFC02

Option Card Fault at Option Port CN5-C
Same type of option card is currently connected

to

oFC03 to oFC11

Option Card Error Occurred at Option Port CN5-C

to

oFC12 to oFC17

to

oFC50 to oFC55

Option Card Error Occurred at Option Port CN5-C

oH

Heatsink Overheat
The heatsink temperature exceeded the overheat pre-alarm level set to L8-02. The default value for L8-02

is determined by drive capacity (o2-04).

Cause

Possible Solution

Surrounding temperature is too high

• Check the temperature surrounding the drive. Verify temperature is within drive specifications.
• Improve the air circulation within the enclosure panel.
• Install a fan or air conditioner to cool the surrounding area.
• Remove anything near the drive that might be producing excessive heat.

5.2 Fault Detection

YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide

139

5

Troubleshooting