F7-22

(3FA)

EtherNet/IP Time Scaling

Sets the scaling factor for the time monitor in EtherNet/IP Class ID 2AH

Object.

Default: 0

Min.: -15

Max.: 15

F7-23 to

F7-32

(3FB to

374)

Dynamic Output Assembly

Parameters

Parameters used in Output Assembly 116. Each parameter contains a

MEMOBUS/Modbus address. The value received for Output Assembly 116

will be written to this corresponding MEMOBUS/Modbus address. A

MEMOBUS/Modbus address value of 0 means that the value received for

Output Assembly 116 will not be written to any MEMOBUS/Modbus register.

Default: 0

F7-33 to

F7-42

(375 to

37E)

Dynamic Input Assembly

Parameters

Parameters used in Input Assembly 166. Each parameter contains a

MEMOBUS/Modbus address. The value sent for Input Assembly 166 will be

read from this corresponding MEMOBUS/Modbus address. A MEMOBUS/

Modbus address value of 0 means that the value sent for Input Assembly 166

is not defined by the user, therefore the option default register value will be

returned.

Default: 0

<1> Parameter setting value is not reset to the default value when the drive is initialized.
<2> Cycle power for setting changes to take effect.
<3> If F7-13 is set to 0, all IP addresses (F7-01 to F7-04) must be unique.