Yaskawa CIMR-PUxA User Manual

Page 152

Advertising
background image

Digital Operator Display

Error Name

Er-08

Rated Slip Error

Cause

Possible Solutions

Motor data entered during Auto-Tuning

was incorrect.

• Make sure the data entered to the T1 parameters match the information written on the motor nameplate.
• Restart Auto-Tuning and enter the correct information.

Results from Auto-Tuning are outside the

parameter setting range or the tuning

process took too long.

• Check and correct faulty motor wiring.
• Perform Rotational Auto-Tuning.

The load was too high during rotational

Auto-tuning.

• Disconnect the motor from machine and restart Auto-Tuning. If motor and load cannot be uncoupled make

sure the load is lower than 30%.

• If a mechanical brake is installed, make sure it is fully lifted during tuning.

Digital Operator Display

Error Name

Er-09

Acceleration Error

Cause

Possible Solutions

The motor did not accelerate for the

specified acceleration time.

• Increase the acceleration time (C1-01).
• Disconnect the machine from the motor if possible.

The load was too high during Rotational

Auto-Tuning.

• Disconnect the motor from machine and restart Auto-Tuning. If motor and load cannot be uncoupled make

sure the load is lower than 30%.

• If a mechanical brake is installed, make sure it is fully lifted during tuning.

Digital Operator Display

Error Name

Er-11

Motor Speed Fault

Cause

Possible Solutions

Torque reference is too high.

• Increase the acceleration time (C1-01).
• Disconnect the machine from the motor if possible.

Digital Operator Display

Error Name

Er-12

Current Detection Error

Cause

Possible Solutions

One of the motor phases is missing:

(U/T1, V/T2, W/T3).

Check motor wiring and correct any problems.

The current exceeded the current rating of

the drive.

• Check motor wiring for a short between motor lines.
• Close any magnetic contactors used between motors.
• Replace the control board or the entire drive. For instructions on replacing the control board, contact

Yaskawa or your nearest sales representative.

The current is too low.

Attempted Auto-Tuning without motor

connected to the drive.

Connect the motor and restart Auto-Tuning.

Current detection signal error.

Replace the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa

or your nearest sales representative.

Digital Operator Display

Error Name

Er-13

Leakage Inductance Error

Cause

Possible Solutions

Drive was unable to complete tuning for

leakage inductance within 300 seconds.

• Check all wiring and correct any mistakes.
• Check the motor rated current value written on the motor nameplate and enter the correct value to T1-04.

Digital Operator Display

Error Name

Er-17

Reverse Prohibited Error

Cause

Possible Solutions

Drive is prohibited from rotating the motor

in reverse while attempting to perform

Inertia Tuning.

• Inertia Auto-Tuning cannot be performed if the drive is restricted from rotating in reverse.
• Assuming it is acceptable for the application to rotate in reverse, set b1-04 to 0 and then perform Inertia

Tuning.

5.5 Auto-Tuning Fault Detection

152

YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide

Advertising