U4: maintenance monitors – Yaskawa CIMR-PUxA User Manual

Page 231

Advertising
background image

No.

(Addr.

Hex)

Name

Description

Analog Output Level

Unit

U3-41

(301F)

Time Hours and Minutes

at 7th Most Recent Fault Displays the time when the seventh most recent fault occurred.

No signal output

available

U3-42

(3020)

Date Year at 8th Most

Recent Fault

Displays the year when the eighth most recent fault occurred.

No signal output

available

U3-43

(3021)

Date Month and Day 8th at

Most Recent Fault

Displays the date and day when the eighth most recent fault occurred.

No signal output

available

U3-44

(3022)

Time Hours and Minutes

at 8th Most Recent Fault Displays the time when the eighth most recent fault occurred.

No signal output

available

U3-45

(3023)

Date Year at 9th Most

Recent Fault

Displays the year when the ninth most recent fault occurred.

No signal output

available

U3-46

(3024)

Date Month and Day at 9th

Most Recent Fault

Displays the date and day when the ninth most recent fault occurred.

No signal output

available

U3-47

(3025)

Time Hours and Minutes

at 9th Most Recent Fault Displays the time when the ninth most recent fault occurred.

No signal output

available

U3-48

(3026)

Date Year at 10th Most

Recent Fault

Displays the year when the tenth most recent fault occurred.

No signal output

available

U3-49

(3027)

Date Month and Day at

10th Most Recent Fault

Displays the date and day when the tenth most recent fault occurred.

No signal output

available

U3-50

(3028)

Time Hours and Minutes

at 10th Most Recent

Displays the time when the tenth most recent fault occurred.

No signal output

available

u

U4: Maintenance Monitors

No.

(Addr.

Hex)

Name

Description

Analog Output Level

Unit

U4-01

(4C)

Cumulative Operation

Time

Displays the cumulative operation time of the drive. The value for the

cumulative operation time counter can be reset in parameter o4-01. Use

parameter o4-02 to determine if the operation time should start as soon as

the power is switched on or only while the Run command is present. The

maximum number displayed is 99999, after which the value is reset to 0.

No signal output

available

1 h

U4-02

(75)

Number of Run

Commands

Displays the number of times the Run command is entered. Reset the

number of Run commands using parameter o4-13. This value will reset to

0 and start counting again after reaching 65535.

No signal output

available

1 Time

U4-03

(67)

Cooling Fan Operation

Time

Displays the cumulative operation time of the cooling fan. The default value

for the fan operation time is reset in parameter o4-03. This value will reset

to 0 and start counting again after reaching 99999.

No signal output

available

1 h

U4-04

(7E)

Cooling Fan Maintenance

Displays main cooling fan usage time as a percentage of its expected

performance life. Parameter o4-03 can be used to reset this monitor.

Replace the fan when this monitor reaches 90%.

No signal output

available

1%

U4-05

(7C)

Capacitor Maintenance

Displays main circuit capacitor usage time as a percentage of their expected

performance life. Parameter o4-05 can be used to reset this monitor.

Replace the capacitor when this monitor reaches 90%.

No signal output

available

1%

U4-06

(7D6)

Soft Charge Bypass Relay

Maintenance

Displays the soft charge bypass relay maintenance time as a percentage of

its estimated performance life. Parameter o4-07 can be used to reset this

monitor.

Replace the soft charge bypass relay when this monitor reaches 90%.

No signal output

available

1%

U4-07

(7D7)

IGBT Maintenance

Displays IGBT usage time as a percentage of the expected performance

life. Parameter o4-09 can be used to reset this monitor.

Replace the IGBT when this monitor reaches 90%.

No signal output

available

1%

U4-08

(68)

Heatsink Temperature

Displays the heatsink temperature.

10 V: 100 °C

1 °C

U4-09

(5E)

LED Check

Lights all segments of the LED to verify that the display is working

properly.

No signal output

available

U4-10

(5C)

kWh, Lower 4 Digits

Monitors the drive output power. The value is shown as a 9-digit number

displayed across two monitor parameters, U4-10 and U4-11.

Example:

12345678.9 kWh is displayed as:

U4-10: 678.9 kWh

U4-11: 12345 MWh

No signal output

available

1 kWh

U4-11

(5D)

kWh, Upper 5 Digits

No signal output

available

1 MWh

B.12 U: Monitors

YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide

231

B

Parameter List

Advertising