Emc guidelines compliance, Guarding against harmful materials, Grounding – Yaskawa CIMR-PUxA User Manual

Page 238: Emc filter installation

Advertising
background image

Drive Model

Fuse Type

Manufacturer: Bussmann

Model

Fuse Ampere Rating (A)

5A0062

<1>

FWP-250A

250

5A0077

<1>

FWP-250A

250

5A0099

<1>

FWP-250A

250

5A0125

<1>

FWP-350A

350

5A0145

<1>

FWP-350A

350

5A0192

<1>

FWP-600A

600

5A0242

<1>

FWP-600A

600

<1> 600 V class drives are not compliant with European Standards.

n

Guarding Against Harmful Materials

When installing IP00/Open Type enclosure drives, use an enclosure that prevents foreign material from entering the drive

from above or below.

n

Grounding

The drive is designed to be used in T-N (grounded neutral point) networks. If installing the drive in other types of grounded

systems, contact your Yaskawa representative for instructions.

u

EMC Guidelines Compliance

This drive is tested according to European standards IEC/EN 61800-3: 2004.

n

EMC Filter Installation

The following conditions must be met to ensure continued compliance with guidelines.

Refer to EMC Filters on page 241

for EMC filter selection.

Installation Method

Verify the following installation conditions to ensure that other devices and machinery used in combination with this drive

also comply with EMC guidelines.

1.

Install an EMC noise filter to the input side specified by Yaskawa for compliance with European standards.

2.

Place the drive and EMC noise filter in the same enclosure.

3.

Use braided shield cable for the drive and motor wiring, or run the wiring through a metal conduit.

4.

Keep wiring as short as possible. Ground the shield on both the drive side and the motor side.

A

B

D

E

C

M

U/T1

V/T2

W/T3

U

V

W

A – Drive

B – 10 m max cable length between drive

and motor

C – Motor

D – Metal conduit

E – Ground wire should be as short as

possible.

Figure C.2 Installation Method

5.

Make sure the protective earthing conductor complies with technical standards and local safety regulations.