<3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives.
<4> The display resolution depends on the ND selection. This value has two decimal places (0.01 kW) if the drive is set for a maximum applicable

motor capacity up to and including 11 kW, and one decimal place (0.1 kW) if the maximum applicable motor capacity is higher than 11 kW.

u

U2: Fault Trace

No.

(Addr.

Hex)

Name

Description

Analog Output Level

Unit

U2-01

(80)

Current Fault

Displays the current fault.

No signal output

available

U2-02

(81)

Previous Fault

Displays the previous fault.

No signal output

available

U2-03

(82)

Frequency Reference at

Previous Fault

Displays the frequency reference at the previous fault.

No signal output

available

0.01 Hz

U2-04

(83)

Output Frequency at

Previous Fault

Displays the output frequency at the previous fault.

No signal output

available

0.01 Hz

U2-05

(84)

Output Current at Previous

Fault

Displays the output current at the previous fault.

No signal output

available

<1>

<2>

U2-07

(86)

Output Voltage at

Previous Fault

Displays the output voltage at the previous fault.

No signal output

available

0.1 Vac

U2-08

(87)

DC Bus Voltage at

Previous Fault

Displays the DC bus voltage at the previous fault.

No signal output

available

1 Vdc

U2-09

(88)

Output Power at Previous

Fault

Displays the output power at the previous fault.

No signal output

available

0.1 kW

U2-11

(8A)

Input Terminal Status at

Previous Fault

Displays the input terminal status at the previous fault. Displayed as in

U1-10.

No signal output

available

U2-12

(8B)

Output Terminal Status at

Previous Fault

Displays the output status at the previous fault. Displays the same status

displayed in U1-11.

No signal output

available

U2-13

(8C)

Drive Operation Status at

Previous Fault

Displays the operation status of the drive at the previous fault. Displays the

same status displayed in U1-12.

No signal output

available

U2-14

(8D)

Cumulative Operation

Time at Previous Fault

Displays the cumulative operation time at the previous fault.

No signal output

available

1 h

U2-15

(7E0)

Soft Starter Speed

Reference at Previous

Fault

Displays the speed reference for the soft starter at the previous fault.

No signal output

available

0.01 Hz

U2-20

(8E)

Heatsink Temperature at

Previous Fault

Displays the temperature of the heatsink when the most recent fault

occurred.

No signal output

available

1 °C

U2-27

(7FA)

Motor Temperature at

Previous Fault (NTC)

Displays the temperature of the motor when the most recent fault occurred. No signal output

available

1 °C

U2-30

(3008)

Date Year at Previous

Fault

Displays the year when the most recent fault occurred.

No signal output

available

U2-31

(3009)

Date Month and Day at

Previous Fault

Displays the date and day when the most recent fault occurred.

No signal output

available

U2-32

(300A)

Time Hours and Minutes at

Previous Fault

Displays the time when the most recent fault occurred.

No signal output

available

<1> The number of decimal places in the parameter value depends on the drive model and the ND selection. This value has two decimal places (0.01

A) if the drive is set for a maximum applicable motor capacity up to and including 11 kW, and one decimal place (0.1 A) if the maximum applicable
motor capacity is higher than 11 kW.

<2> When reading the value of this monitor via MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current.

B.12 U: Monitors

YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide

229