Descriptions, Section 5.6 – Texas Instruments TMS320TCI648x User Manual

Page 117

Advertising
background image

www.ti.com

5.6

Peripheral Global Enable Status Register (GBL_EN_STAT)

SRIO Registers

The peripheral global enable status register (GBL_EN_STAT) is shown in

Figure 67

and described in

Table 45

. For additional programming information, see

Section 2.3.10

.

Figure 67. Peripheral Global Enable Status Register (GBL_EN_STAT) - Address 0034h

31

24

Reserved

R-0

23

16

Reserved

R-0

15

10

9

8

BLK8_EN_

BLK7_EN_

Reserved

STAT

STAT

R-0

R-1

R-1

7

6

5

4

3

2

1

0

BLK6_EN_

BLK5_EN_

BLK4_EN_

BLK3_EN_

BLK2_EN_

BLK1_EN_

BLK0_EN_

GBL_EN_

STAT

STAT

STAT

STAT

STAT

STAT

STAT

STAT

R-1

R-1

R-1

R-1

R-1

R-1

R-1

R-1

LEGEND: R = Read only; -n = Value after reset

Table 45. Peripheral Global Enable Status Register (GBL_EN_STAT) Field Descriptions

Bit

Field

Value

Description

31–10

Reserved

0

These read-only bits return 0s when read.

9

BLK8_EN_STAT

Block 8 enable status. Logical block 8 is SRIO port 3.

0

Logical block 8 is in reset with its clock off.

1

Logical block 8 is enabled with its clock running.

8

BLK7_EN_STAT

Block 7 enable status. Logical block 7 is SRIO port 2.

0

Logical block 7 is in reset with its clock off.

1

Logical block 7 is enabled with its clock running.

7

BLK6_EN_STAT

Block 6 enable status. Logical block 6 is SRIO port 1.

0

Logical block 6 is in reset with its clock off.

1

Logical block 6 is enabled with its clock running.

6

BLK5_EN_STAT

Block 5 enable status. Logical block 5 is SRIO port 0.

0

Logical block 5 is in reset with its clock off.

1

Logical block 5 is enabled with its clock running.

5

BLK4_EN_STAT

Block 4 enable status. Logical block 4 is the message receive unit (RXU).

0

Logical block 4 is in reset with its clock off.

1

Logical block 4 is enabled with its clock running.

4

BLK3_EN_STAT

Block 3 enable status. Logical block 3 is the message transmit unit (TXU).

0

Logical block 3 is in reset with its clock off.

1

Logical block 3 is enabled with clock running.

3

BLK2_EN_STAT

Block 2 enable status. Logical block 2 is the memory access unit (MAU).

0

Logical block 2 is in reset with its clock off.

1

Logical block 2 is enabled with its clock running.

2

BLK1_EN_STAT

Block 1 enable status. Logical block 1 is the Load/Store module, which is
comprised of the four Load/Store units (LSU1, LSU2, LSU3, and LSU4).

0

Logical block 1 is in reset with its clock off.

1

Logical block 1 is enabled with its clock running.

SPRUE13A – September 2006

Serial RapidIO (SRIO)

117

Submit Documentation Feedback

Advertising