SRIO Registers

Table 57. SERDES Receive Channel Configuration Register n (SERDES_CFGRXn_CNTL) Field

Descriptions (continued)

Bit

Field

Value

Description

15–14

LOS

Loss of signal. Enables loss of signal detection with 2 selectable thresholds.

00b

Disabled. Loss of signal detection disabled.

01b

High threshold. Loss of signal detection threshold in the range 85 to 195mV

dfpp

.

This setting is suitable for Infiniband.

10b

Low threshold. Loss of signal detection threshold in the range 65 to 175mV

dfpp

.

This setting is suitable for PCI-E and S-ATA.

11b

Reserved

13–12

ALIGN

Symbol alignment. Enables internal or external symbol alignment.

00b

Alignment disabled. No symbol alignment will be performed while this setting is
selected, or when switching to this selection from another.

01b

Comma alignment enabled. Symbol alignment will be performed whenever a
misaligned comma symbol is received.

10b

Alignment jog. The symbol alignment will be adjusted by one bit position when this
mode is selected (that is, the ALIGN value changes from 0xb to 1xb).

11b

Reserved

11

Reserved

0

This read-only bit returns 0 when read.

10–8

TERM

001b

Input termination. The only valid value for this field is 001b. This value sets the
common point to 0.8 VDDT and supports AC coupled systems using CML
transmitters. The transmitter has no effect on the receiver common mode, which is
set to optimize the input sensitivity of the receiver. Common mode termination is
via a 50 pF capacitor to VSSA.

7

INVPAIR

Invert polarity. Inverts polarity of RIORXn and RIORXn.

0

Normal polarity. RIORXn is considered to be positive data and RIORXn negative.

1

Inverted polarity. RIORXn is considered to be negative data and RIORXn positive.

6–5

RATE

Operating rate. Selects full, half, or quarter rate operation.

00b

Full rate. Two data samples taken per PLL output clock cycle.

01b

Half rate. One data sample taken per PLL output clock cycle.

10b

Quarter rate. One data sample taken every two PLL output clock cycles.

11b

Reserved

4–2

BUSWIDTH

000b

Bus width. Always write 000b to this field, to indicate a 10-bit-wide parallel bus to
the clock. All other values are reserved. See

Section 2.3.2.1

for an explanation of

the bus.

1

Reserved

0

Always write 0 to this reserved bit.

0

ENRX

Enable receiver

0

Disable this receiver.

1

Enable this receiver.

Table 58. EQ Bits

CFGRX[22–19]

Low Freq Gain

Zero Freq (at e

28

(min))

0000b

Maximum

0001b

Adaptive

Adaptive

001xb

Reserved

01xxb

Reserved