Repetition shots screen – Spectra Precision Survey Pro CE v3.6 User Manual User Manual

Page 108

Advertising
background image

User’s Manual

102

BS > FS ^ FS > BS

: Shoot backsight, shoot foresight, reverse

scope, shoot foresight, shoot backsight

BS > FS ^> BS > FS

: Shoot backsight, shoot foresight, reverse

scope, shoot backsight, shoot foresight

BS ^ BS > FS ^ FS

: Shoot backsight, reverse scope, shoot

backsight, shoot foresight, reverse scope, shoot foresight

FS ^ FS > BS ^ BS

: Shoot foresight, reverse scope, shoot

foresight, shoot backsight, reverse scope, shoot backsight

FS > BS ^ BS > FS

: Shoot foresight, shoot backsight, reverse

scope, shoot backsight, shoot foresight

FS > BS ^> FS > BS

: Shoot foresight, shoot backsight, reverse

scope, shoot foresight, shoot backsight

Repetition Shots Screen

After the repetition settings are configured for your particular
situation, the Repetition Shots screen is accessed where the actual
shots are performed.

1. Select



6XUYH\ , 5HSHWLWLRQ 6KRWV from the

Main Menu. If you have not already defined
your backsight, you will need to do so before
you can access the Repetition Shots screen.

2. Enter

the

Foresight

point name,

Number of

Sets

and

HR

(rod height) in the appropriate

fields.

3. Tap

the

$OO button to start the process of

shooting all of the sets using the sequence
selected in the Repetition Settings screen.

4. Prompts will open after every shot that instruct you on which

point to shoot next and when you when you need to flop the scope.

If at least three sets were performed, the

Average (of)

and

Worst

Residual

fields will be filled in after the final shot is taken. The

Average (of)

values are simply average measurements for all of the

shots taken. The

Worst Residual

is the angle or distance

Advertising