22

the design elevation at the node furthest from the centerline of the
current segment. When unchecked, cut and fill information will be
computed from the design elevation of the segment at the current rod
location.

Note: If staking extends beyond the end of the cross section, the cut /
fill information will always be computed from the design elevation at
the node furthest from the centerline of the current segment.

;

Write Cut Sheet Data Only (No Store Point)

: When checked, as-

built points are not stored to the JOB file when staking points; only
the raw data is written to the RAW file.

;

Display Left / Right From Rod (non-remote)

: When checked, the

move left or right information will be presented from the rod person’s
point of view. When unchecked, it will be presented from the total
station’s point of view. (This option only applies when a robotic total
station is selected in the Instrument Settings.)

;

Display Left / Right From Rod (remote)

: When checked, the move

left or right information will be presented from the rod person’s point
of view. When unchecked, it will be presented from the total station’s
point of view. (This option only applies when a non-robot total station
is selected in the Instrument Settings.)

;

Prompt for Layer

: when checked, a prompt to select a layer will

appear before any new point is stored from only the routines under
the Stakeout menu.

;

Prompt for Attributes

: when checked, a prompt to select feature

information will appear before any new point is stored from only the
routines under the Stakeout menu. This also requires that a feature
file be selected from the Files Settings card, described earlier.

Note: There is no

Prompt for Description

checkbox as in the Survey

Settings because you will always be prompted for a description when
storing a point from a stakeout routine.

Horizontal Distance Tolerance

: this setting affects the Remote

Staking and Stake to Line routines. When staking to a line and the
prism is located at a perpendicular distance to the specified line that

Advertising