Master Programming Level

Programming

ANN-LED Point Option - Alarm Only (for use with ANN-RLED module)

If Point is selected as the module option and the module is programmed to annunciate alarms only,
the first ten LEDs on the first ANN-LED module will display the system status information. The
remaining 30 LEDs on the first module and the last 30 LEDs on each additional module will dis-
play the active/alarm status of each point in the Point Range programmed for that particular mod-
ule. The points that will be annunciated on a particular ANN-LED module depend on the
programming options selected as far a which SLC loop and the device type (detector or module) to
be annunciated. The LED assignments for each ANN-LED module will be as follows.

The LED assignments for the modules annunciating Point Ranges 61 - 90, 91 - 120, 121 - 150, and
151 - 159, will follow the same pattern as the second ANN-RLED module.

Alarm Silenced

NAC 1 Fault

NAC 2 Fault

NAC 3 Fault

NAC 4 Fault

Earth Fault

Battery Fault

Charger Fault

Disabled

Maintenance

Point 01

Active/Alarm

Point 02

Active/Alarm

Point 03

Active/Alarm

Point 04

Active/Alarm

Point 05

Active/Alarm

Point 06

Active/Alarm

Point 07

Active/Alarm

Point 08

Active/Alarm

Point 09

Active/Alarm

Point 10

Active/Alarm

Point 11

Active/Alarm

Point 12

Active/Alarm

Point 13

Active/Alarm

Point 14

Active/Alarm

Point 15

Active/Alarm

Point 16

Active/Alarm

Point 17

Active/Alarm

Point 18

Active/Alarm

Point 19

Active/Alarm

Point 20

Active/Alarm

Point 21

Active/Alarm

Point 22

Active/Alarm

Point 23

Active/Alarm

Point 24

Active/Alarm

Point 25

Active/Alarm

Point 26

Active/Alarm

Point 27

Active/Alarm

Point 28

Active/Alarm

Point 29

Active/Alarm

Point 30

Active/Alarm

ANN-RLED Module #1 (Point Range 01 - 30)

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

Point 31

Active/Alarm

Point 32

Active/Alarm

Point 33

Active/Alarm

Point 34

Active/Alarm

Point 35

Active/Alarm

Point 36

Active/Alarm

Point 37

Active/Alarm

Point 38

Active/Alarm

Point 39

Active/Alarm

Point 40

Active/Alarm

Point 41

Active/Alarm

Point 42

Active/Alarm

Point 43

Active/Alarm

Point 44

Active/Alarm

Point 45

Active/Alarm

Point 46

Active/Alarm

Point 47

Active/Alarm

Point 48

Active/Alarm

Point 49

Active/Alarm

Point 50

Active/Alarm

Point 51

Active/Alarm

Point 52

Active/Alarm

Point 53

Active/Alarm

Point 64

Active/Alarm

Point 55

Active/Alarm

Point 56

Active/Alarm

Point 57

Active/Alarm

Point 58

Active/Alarm

Point 59

Active/Alarm

Point 60

Active/Alarm

ANN-RLED Module #2 (Point Range 31 - 60)