Fire-Lite MS-9600LSC Addressable Fire Alarm Control Panel User Manual

Page 9

Advertising
background image

MS-9600LS Series Manual — P/N 52646:B2 2/12/2010

9

It is imperative that the installer understand the requirements of the Authority Having Jurisdiction
(AHJ) and be familiar with the standards set forth by the following regulatory agencies:

Underwriters Laboratories Standards

NFPA 72 National Fire Alarm Code

CAN/ULC - S527-99 Standard for Control Units for Fire Alarm Systems

NFPA Standards
NFPA 72 National Fire Alarm Code

NFPA 70 National Electrical Code

Underwriters Laboratories Documents:

UL 38 Manually Actuated Signaling Boxes

UL 217 Smoke Detectors, Single and Multiple Station

UL 228 Door Closers–Holders for Fire Protective Signaling Systems

UL 268 Smoke Detectors for Fire Protective Signaling Systems

UL 268A Smoke Detectors for Duct Applications

UL 346 Waterflow Indicators for Fire Protective Signaling Systems

UL 464 Audible Signaling Appliances

UL 521 Heat Detectors for Fire Protective Signaling Systems

ANSI/UL 864, Control Units and Accessories for Fire Alarm Systems

UL 1481 Power Supplies for Fire Protective Signaling Systems

UL 1610 Central Station Burglar Alarm Units

UL 1638 Visual Signaling Appliances

UL 1971 Signaling Devices for Hearing Impaired

UL 2017 General-Purpose Signaling Devices and System
CAN/ULC - S524-01 Standard for Installation of Fire Alarm Systems

CAN/ULC - S527-99 Standard for Control Units for Fire Alarm Systems

CAN\ULC - S559-04 Equipment for Fire Signal Receiving Centers and Systems

CAN\ULC - S561-03 Installation and Services for Fire Signal Receiving Centers and Systems

Note: MS-9600LSE/MS-9600UDLSE is not ULC listed for Canadian applications
This Class (A) digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe (A) est conforme à la norme NMB-003 du Canada.
FM Approved to ANSI/UL 864
Other:
EIA-232E Serial Interface Standard

EIA-485 Serial Interface Standard

NEC Article 250 Grounding

NEC Article 300 Wiring Methods

NEC Article 760 Fire Protective Signaling Systems

Applicable Local and State Building Codes

Requirements of the Local Authority Having Jurisdiction (LAHJ)
Fire-Lite Documents:
Fire-Lite Device Compatibility

Document #15384

SLC Wiring Manual

Document #51309

ACS Series Annunciators

Document #51480

411UD Communicator/Transmitter

Document #50759

411UDAC Communicator/Transmitter

Document #51073

CHG-120F Battery Charger

Document #50888

CHG-75 Battery Charger

Document #51315

LDM Series Lamp Driver Modules

Document #50055

LCD-80F Remote Fire Annunciator

Document #51338

ACM-8RF Relay Control Module

Document #50362

DACT-UD2 Manual

Document #53037

IDACT Communicator/Transmitter

Document #53109

ANN-80 Installation Document

Document #52749

ANN-(R)LED Installation Document

Document #53032

ANN-I/O Installation Document

Document #151416

ANN-RLY Installation Document

Document #53033

ANN-S/PG Installation Document

Document #151417

ACC-25/50(ZS/T) Manual

Document #51889

This product has been certified to comply with the requirements in the ANSI/UL 864, Standard for Control
Units and Accessories for Fire Alarm Systems, 9th Edition. Operation of this product with products not tested
for ANSI/UL 864, 9th Edition has not been evaluated. Such operation requires the approval of the local
Authority Having Jurisdiction (AHJ).

Before proceeding, the installer should be familiar with the following documents.

Advertising