Repeat this step for each POINT PAIR prompt for mm equal to 03 through 21 (or less).

7. Press the

and the display advances to the next custom curve to be programmed. Refer to the begin-

ning of this section, page 4-15.

4.1.4 DERIVED VARIABLES

Derived Variables utilize math to DERIVE a value from other variables and/or constants. Derived Variables are

available only if MATH was specified and present in the model number order matrix.

From the Normal Display, press the

until CONFIGURATION is seen in the lower display line. If PASS-

WORD appears in the lower display line, the correct "password" will need to be entered before access to Configu-

ration is allowed. If CONFIGURATION is not displayed, then Configuration has been disabled. Refer to Section

9, Enables and Passwords, for instructions to enable Configuration.

With CONFIGURATION in the display, press the

, then the

until DERIVED VARIABLES appears in

the lower display line.

1. Press the

to display DV NUMBER.

Press the

to change, then

to

desired number, then press the

.

DV NUMBER

1

Selections

1 to 12