5 cp14 c1, debug status and control register, Table 11-10, Debug status and control register functions -14 – ARM Cortex R4F User Manual

Page 283: Figure 11-5, Debug status and control register format -14

Advertising
background image

Debug

ARM DDI 0363E

Copyright © 2009 ARM Limited. All rights reserved.

11-14

ID013010

Non-Confidential, Unrestricted Access

11.4.5

CP14 c1, Debug Status and Control Register

The DSCR contains status and control information about the debug unit. Figure 11-5 shows the
bit arrangement of the DSCR.

Figure 11-5 Debug Status and Control Register format

Table 11-10 shows how the bit values correspond with Debug Status and Control Register
functions.

31 30 29 28

16 15 14 13 12 11 10

6 5

2 1 0

MOE

9

7

8

Core halted

Core restarted

26 25 24 23

PipeAdv

InstrCompl

22 21 20 19 18

Monitor mode

Halting mode

ARM

DbgAck

IntDis

Comms

Sticky imprecise abort

Sticky Undefined

Reserved

Sticky precise abort

DTR access

Discard
imprecise
abort

27

Reserved

DTRTXfull

DTRRXfull

Reserved

Reserved

Reserved

Table 11-10 Debug Status and Control Register functions

Bits

Field

Function

[31]

Reserved

RAZ on reads, SBZP on writes.

[30]

DTRRXfull

The DTRRXfull flag:
0 = Read-DTR, DTRRX, empty, reset value
1 = Read-DTR, DTRRX, full.
When set, this flag indicates to the processor that there is data available to read at the
DTRRX. It is automatically set on writes to the DTRRX by the debugger, and is cleared
when the processor reads the CP14 DTR. If the flag is not set, the DTRRX returns an
Unpredictable value.

[29]

DTRTXfull

The DTRTXfull flag:
0 = Write-DTR, DTRTX, empty, reset value
1 = Write-DTR, DTRTX, full.
When clear, this flag indicates to the processor that the DTRTX is ready to receive data. It
is automatically cleared on reads of the DTRTX by the debugger, and is set when the
processor writes to the CP14 DTR. If this bit is set and the processor attempts to write to
the DTRTX, the register contents are overwritten and the DTRRXfull flag remains set.

[28:26]

Reserved

RAZ on reads, SBZP on writes.

[25]

PipeAdv

Sticky pipeline advance read-only bit. This bit enables the debugger to detect whether the
processor is idle. In some situations, this might mean that the system bus port is
deadlocked. This bit is set to 1 when the processor pipeline retires one instruction. It is
cleared by a write to DRCR[3].
0 = no instruction has completed execution since the last time this bit was cleared
1 = an instruction has completed execution since the last time this bit was cleared.