Dc = t – Rockwell Automation 1333 Drive, 3/4-5HP, 230-575V Series D User Manual

Page 134

Advertising
background image

Application Data

Appendix D

D-7

Step 8 -- Determine if the Duty Cycle is within the Brake's Capability

DC = [ ]

×

100

[ ]

DC = t

2

×

100

t

1

T

1

= The motor's cycle time

T

2

= The motor's decel time

DC = %

Find the intersection of

P

%

and the motor’s decel time

DC in the chart

below. If the point of intersection is below the curve, the duty cycle is
within the brake’s limits. If the point is above the curve, the duty cycle is
beyond the brake’s limits but may be modified by increasing the motor’s
cycle time

t

1

.

0

30

10

20

5

15

25

30

40

50

10

20

35

45

5

15

25

55

35

45

40

50

80

60

70

65

75

90

85

95

P%

100

0

Duty Cycle DC in %

Advertising