Function Checks

- Motor Disconnected

Figure 6Ć3 -- 3/4Ć20ĂHP (.55Ć15kW) Controls

Step 5 -- Local/Remote Control Enable Check

Max Speed Settings Check

Start the drive by pressing either directional start pushbutton. The
pushbutton will light. Press and hold the increment pushbutton and watch
the display increase. Release thew pushbutton when the display reaches

60.00

Hz or maximum speed.

Step 6 -- Monitor Mode Settings Check

Press the select pushbutton once. The main display will flash and show the
last manual set speed entered.

Press the select pushbutton again.

A0.

will be shown in the mode display,

drive output amps in the main display, as set by Parameter 57.

Press the select pushbutton again. The mode display will flash and show

0ĂI.

to indicate the parameter being viewed, and the main display will show

005.0

, the accel time set by Parameter 1.

Press the pushbutton again and

60.00Ă

Hz will again be displayed.

Step 7 -- Reverse Enable Check

Accel and Decel Settings Check

Press the other directional start pushbutton. The pushbutton will light and

the drive display will ramp down to

0.00

Hz within the decel time set by

Parameter 2, then immediately ramp up to

60.00

Hz, the maximum speed

presently programmed by Parameter 3, within the accel time set by
Parameter 1. Reversing is enabled or disabled by Parameter 10.