Parameter, Bias frequency, Gain frequency – Rockwell Automation 1333 Drive, 3/4-5HP, 230-575V Series D User Manual

Page 87

Advertising
background image

Operation and Programming

Chapter 5

5-44

Bias and Gain Settings

➊ 100% of Output Frequency

100% of Input Frequency Signal

0%

Parameter 53 = 0%

Ac

celeratio

n

When Bias Frequency
is Less Than Gain
a Directly Proportional
Input Frequency Signal
is Produced

Bias Frequency Less Than Gain

Parameter 54

➊ 100% of Output Frequency = 50 Hz if Parameter 3 = 50
60 Hz if Parameter 3 = 60
Paramer 15 if Parameter 3 = FF

➊ 100% of Output Frequency

100% of Input Frequency Signal

Bias Frequency Greater Than Gain

0%

0%

Parameter 53

n

o

it

a

r

e

l

e

c

e

D

When Bias Frequency
is Greater Than Gain
an Inversely Proportional
Input Frequency Signal
is Produced

Parameter 54

Parameter

53

-- Bias Frequency

Units

= Hertz

Range

= 00.00/400.0

Factory Setting = 00.00
From 00.50-400.0 Hz, Parameter 53 sets the Bias Frequency in .01 Hz
increments.

From 100.0-400.0 Hz, Parameter 53 sets the Bias Frequency in 0.1 Hz
increments.

Parameter

54

-- Gain Frequency

Units

= Hertz

Range

= 00.50/400.0

Factory Setting = 60.00
From 00.50-400.0 Hz, Parameter 54 sets the Gain Frequency in .01 Hz
increments.
From 100.0-400.0 Hz, Parameter 54 sets the Gain Frequency in 0.1 Hz
increments.