Max Speed Settings
Important: The maximum allowable drive output frequency will be
determined by the lowest programmed value of any of the following
parameters:
•
Parameter 3 Frequency Range
•
Parameter 15 Maximum Frequency
•
Parameter 51 Upper Frequency Clamp
•
Parameter 53 Bias Frequency –– If Parameter 53 is Higher Than
Parameter 54
•
Parameter 54 Gain Frequency –– If Parameter 54 is Higher Than
Parameter 53
Max Speed Settings
100% of Output Frequency
0%
0%
Parameter 16
100% of Output Voltage
n
o
it
a
r
e
l
e
c
c
A
Parameter 15
0%
0%
100% of Output Frequency
Parameter 15 = Parameter 16