background image

Load Initial Configuration Values

Chapter 7

7-32

may also be obtained by referencing Section 3 of the Plastic Molding
Module Reference Manual (pub. no. 1771-6.5.88).

EndĆof Profile SetĆoutput Values

(FCC33 Ć 36, SCC33 Ć 36, TCC33 Ć 36, LPC33 Ć 36, FOC33 Ć 36,

SOC33 Ć 36, TOC33 Ć 36, OSC33 Ć 36, EAC33 Ć 36, ERC33 Ć 36)

The QDC module sets its outputs equal to these set-output values every
time it completes the appropriate profile or ejector stroke and other
configurations do not require the QDC module to “bridge” to the next
logical profile or stroke. These outputs remain in effect until the next
logical profile begins or the module is stopped using DYC02-B15. The
ramp rates defined above are in effect for output movement to these
set-output values.

Enter values for all End-of Profile Set-outputs that correspond to zero
pressure or flow. The valve spanning procedures presented in chapter 9
require these initial values. A detailed discussion of this type of setpoint is
presented in chapter 10 to assist you in selecting the correct, final values
required by your application. Additional information may also be obtained
by referencing Section 3 of the Plastic Molding Module Reference Manual
(pub. no. 1771-6.5.88).