Enter Your SWTL Configuration Values Here

Configure the QDC Module's

Inputs and Outputs

Chapter 3

3-18

Configure the QDC module for SWTL as follows:

1.

Determine these SWTL values for clamp and/or ejector travel with
respect to the range of physical travel.

SWTL deadband
Maximum SWTL
Minimum SWTL

2.

Record non-zero SWTL values on Worksheet 3-F. Zero values
disable the corresponding SWTLs.

ATTENTION: Leaving your SWTL settings at zero (MCC27,
MCC28, MCC41, MCC42) inhibits the QDC module from
performing this safety function.

Worksheet 3ĆF

SWTL Configuration Values

Control Word

ProĆSet 600 Addr. Value

Description

Units

MCC27

N41:23

Clamp Minimum SWTL

Clamp Axis Measured from zero

1

MCC28

N41:24

Clamp Maximum SWTL

Clamp Axis Measured from zero

1

MCC29

N41:25

10

Clamp SWTL Deadband

As noted

1

MCC41

N41:37

Ejector Minimum SWTL

Ejector Axis Measured from zero

1

MCC42

N41:38

Ejector Maximum SWTL

Ejector Axis Measured from zero

1

MCC43

N41:39

10

Ejector SWTL Deadband

As noted

1

1

Incremental Distance

00.00 to 99.99 Inches

000.0 to 999.9 Millimeters

You may now download your adjusted values to the QDC module using
the MCC download procedure presented earlier in this chapter.