Overview of the Clamp and Eject Mode
Chapter 1
1-2
You control clamp operation with these phases:
clamp
close
low pressure close
clamp
open
open
slow
Figure 1.1
Clamp Portion of a Typical Machine Cycle
Inject
Ejector retract
1st
Close
2nd
Close
3rd
Close
1st
Open
2nd
Open
3rd
Open
Low Pressure
Close
Open
Slow
Ejector advance
Clamp Close
Three separate clamp close profiles may be configured:
first
close
second
close
third
close
You may select from these control modes:
velocity vs. position
pressure vs. position
Use Clamp Close to move the platen from the fully open position (L) to
some position X at a relatively high velocity or pressure. X is a position
relatively close to the stationary platen yet far enough away to allow
deceleration into Low Pressure Close. This prevents the platens from
coming together at a high velocity.