Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual

Page 72

Advertising
background image

Select Command and Status Bits

to Sequence Machine Operation

Chapter 6

6-5

Table 6.G

Command Bits to Enable or Disable Ejector Profiles

Bit Description:

QDC Block Addr.:

0 = start ejector profile on clamp position

1 = start ejector profile on command

EPC03ĆB08

0 = ejector profile enabled

1 = ejector profile disabled

EPC03ĆB09

0 = run ejector profile without interruption

1 = stop and notify @ end of ejector stroke

EPC03ĆB12

Table 6.H

Miscellaneous Status Bits to Trigger New Ejector Events

Reason for Using:

Bit Description:

QDC Block

Addr.:

To shift solenoids before starting next

ejector stroke after the 1st advance

stroke

Ejector profile stopped at end of

stroke

SYS03ĆB08

To prevent starting ejector retract

Ejector forward dwell timer is timing

SYS03ĆB10

To start ejector retract

Ejector fully advanced

SYS03ĆB12

To start ejector retract when

tip stroking is ON

Ejector is beyond tip advance position SYS03ĆB13

To start ejector advance when

tip stroking is ON

Ejector is inside tip retract position

SYS03ĆB14

To start ejector advance

Ejector fully retracted

SYS03ĆB15