Enter Your Values Here

Blank Worksheets

Appendix A

A-25

Worksheet 7-I (continued)

Ejector Advance (EAC) Configuration Block

Control Word ProĆSet 600 Addr. Value

Description

Units

EAC05

N45:1

Minimum ERC

PercentageĆĆVelocity

Percent

8

EAC06

N45:2

Minimum ERC

PercentageĆĆPressure

Percent

8

EAC08

N45:4

Profile Watchdog Timer Preset

Time

1

EAC09

N45:5

Output #1 SetĆOutput Value during Advance

Percent Signal Output

4

EAC10

N45:6

Output #2 SetĆOutput Value during Advance

Percent Signal Output

4

EAC11

N45:7

Output #3 SetĆOutput Value during Advance

Percent Signal Output

4

EAC12

N45:8

Output #4 SetĆOutput Value during Advance

Percent Signal Output

4

EAC17

N45:13

Output #1 Acceleration Ramp Rate during Advance

Percent Signal Output per Second

5

EAC18

N45:14

Output #2 Acceleration Ramp Rate during Advance

Percent Signal Output per Second

5

EAC19

N45:15

Output #3 Acceleration Ramp Rate during Advance

Percent Signal Output per Second

5

EAC20

N45:16

Output #4 Acceleration Ramp Rate during Advance

Percent Signal Output per Second

5

EAC25

N45:21

Output #1 Deceleration Ramp Rate during Advance

Percent Signal Output per Second

5

EAC26

N45:22

Output #2 Deceleration Ramp Rate during Advance

Percent Signal Output per Second

5

EAC27

N45:23

Output #3 Deceleration Ramp Rate during Advance

Percent Signal Output per Second

5

EAC28

N45:24

Output #4 Deceleration Ramp Rate during Advance

Percent Signal Output per Second

5

EAC33

N45:29

Output #1 SetĆOutput Value at EndĆofĆAdvance

Percent Signal Output

4

EAC34

N45:30

Output #2 SetĆOutput Value at EndĆofĆAdvance

Percent Signal Output

4

EAC35

N45:31

Output #3 SetĆOutput Value at EndĆofĆAdvance

Percent Signal Output

4

EAC36

N45:32

Output #4 SetĆOutput Value at EndĆofĆAdvance

Percent Signal Output

4

EAC41

N45:37

Pressure Minimum Control Limit

Pressure

3

EAC42

N45:38

Pressure Maximum Control Limit

Pressure

3

EAC43

N45:39

Selected Pressure Valve Output for Minimum

Percent Signal Output

4

EAC44

N45:40

Selected Pressure Valve Output for Maximum

Percent Signal Output

4

EAC45

N45:41

Velocity Minimum Control Limit

Velocity along Axis

2

EAC46

N45:42

Velocity Maximum Control Limit

Velocity along Axis

2

EAC47

N45:43

Selected Velocity Valve Output for Minimum

Percent Signal Output

4

EAC48

N45:44

Selected Velocity Valve Output for Maximum

Percent Signal Output

4

EAC49

N45:45

Proportional Gain for Pressure Control

None

EAC50

N45:46

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

EAC51

N45:47

Derivative Gain for Pressure Control

Time (Algorithm)

7

Time

1

EAC52

N45:48

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

EAC53

N45:49

Feed Forward Gain for Velocity Control

None

EAC57

N45:53

Profile High Pressure Alarm Setpoint

Pressure

3

1

Time

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI 00.00 to 99.99

000.0 to 999.9 Millimeters per Sec 000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent