Overview of the Remaining

Configuration Procedures

Chapter 4

4-6

3.

Start the download procedure by setting the corresponding download
bit (Table 4.A) in your PLC-5 data table.

4.

Watch the bit you set in step 3 and wait for Pro-Set 600 software to
reset it to zero. This indicates the PLC-5 processor has transferred
the block to the QDC module.

5.

Observe the value of SYS62 (N40:214) in your PLC-5 data table:

If SYS62 = 0, the QDC module detected no errors. Go to step 6.
If SYS62

0, the QDC module detected an error. Go to step 8.

6.

Since the QDC module did not detect a programming error, check
Table 4.A to see if the subject block has a required companion block.

Important: When downloading multiple subject blocks that share the
same companion block, you may download the companion block:

after each subject block
once after the last subject block

To simplify troubleshooting your data entry (programming) errors during
initial configuration procedures, we recommend that you download the
companion block after each subject block. Otherwise, the procedure to
correct multiple errors becomes too complex.

7.

Complete the procedure as follows:

a.

If subject block has a required companion block, return to step 2
and repeat the procedure for the next block or companion block.

b.

If the subject block is the companion block, download it.
Return to step 2 to download additional blocks if required.

8.

The QDC module detected a programming error. Interpret the error
code returned by the QDC module in SYS62. The code identifies the
first detected programming error in the subject block whose ID is
reported in SYS61 (N40:213). Refer to Section 2 of the Plastic
Molding Module Reference Manual (publication 1771-6.5.88) for
how to interpret and correct the cause of programming errors.

9.

Correct the error in the PLC-5 data table corresponding to the subject
block. Since you may have more than one programming error in the
subject block, return to step 4 and repeat the download procedure
until you have corrected all errors in this block. Then SYS62 = 0.