Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual

Page 223

Advertising
background image

Enter Your Values Here

Blank Worksheets

Appendix A

A-23

Worksheet 7-H

(continued)

Clamp Open Slow (OSC) Configuration Block

Control Word ProĆSet 600 Addr. Value

Description

Units

OSC05

N43:481

Minimum ERC

PercentageĆĆVelocity

Percent

8

OSC06

N43:482

Minimum ERC

PercentageĆĆPressure

Percent

8

OSC08

N43:484

Profile Watchdog Timer Preset

Time

1

OSC09

N43:485

Output #1 SetĆOutput Value during Profile

Percent Signal Output

4

OSC10

N43:486

Output #2 SetĆOutput Value during Profile

Percent Signal Output

4

OSC11

N43:487

Output #3 SetĆOutput Value during Profile

Percent Signal Output

4

OSC12

N43:488

Output #4 SetĆOutput Value during Profile

Percent Signal Output

4

OSC17

N43:493

Output #1 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

OSC18

N43:494

Output #2 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

OSC19

N43:495

Output #3 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

OSC20

N43:496

Output #4 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

OSC25

N43:501

Output #1 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

OSC26

N43:502

Output #2 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

OSC27

N43:503

Output #3 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

OSC28

N43:504

Output #4 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

OSC33

N43:509

Output #1 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

OSC34

N43:510

Output #2 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

OSC35

N43:511

Output #3 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

OSC36

N43:512

Output #4 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

OSC41

N43:517

Pressure Minimum Control Limit

Pressure

3

OSC42

N43:518

Pressure Maximum Control Limit

Pressure

3

OSC43

N43:519

Selected Pressure Valve Output for Minimum

Percent Signal Output

4

OSC44

N43:520

Selected Pressure Valve Output for Maximum

Percent Signal Output

4

OSC45

N43:521

Velocity Minimum Control Limit

Velocity along Axis

2

OSC46

N43:522

Velocity Maximum Control Limit

Velocity along Axis

2

OSC47

N43:523

Selected Velocity Valve Output for Minimum

Percent Signal Output

4

OSC48

N43:524

Selected Velocity Valve Output for Maximum

Percent Signal Output

4

OSC49

N43:525

Proportional Gain for Pressure Control

None

OSC50

N43:526

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

OSC51

N43:527

Derivative Gain for Pressure Control

Time (Algorithm)

7

Time

1

OSC52

N43:528

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

OSC53

N43:529

Feed Forward Gain for Velocity Control

None

OSC57

N43:533

Profile High Pressure Alarm Setpoint

Pressure

3

1

Time

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI 00.00 to 99.99

000.0 to 999.9 Millimeters per Sec 000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999 00.00 to 99.99 Minutes 00.00 to 99.99 Minutes 00.00 to 99.99

00.00 to 99.99 Seconds